<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-23 02-20-42
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 94 dBuV PROFline
Pilot RDS Phase Difference
6.6 kHz 4.0 kHz 90 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 50 kHz 19139 9,1907
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,7 dBr 1,01 dBr 2,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"PROFline" 8000 0 (No PTY) 0 0 1 1 --:--
RT
-
AF EON
-
FM Scope Max at: 50 kHz MIN: 10 kHz % above 76 kHz: 9,1907 Acquired: 2026/01/23 2.19.37 Total samples: 19139 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 2,4 dBr MIN: -1,7 dBr AVE: 1,01 dBr % above 12,2 dBr: 0,0 Last value: -0,7 dBr (2026/01/23 2.19.37) 02.06 02.08 02.10 02.12 02.14 02.16 02.18 -2 -1 0 1 2 3 Pm [dBr]